Skip to main content
Listing · Posted 22 Feb

MedImage MI-3000T, Boston

A 2019 MedImage MI-3000T 3.0-tesla MRI system, decommissioned from a Dutch regional hospital following a full equipment refresh. Helium level at 98% (topped-up 01/2026), 4,210 scan-hours since last cold-ramp. Includes the 70 cm wide-bore magnet, 48-channel RF chain, and the full control room bundle (operator workstation, patient monitoring cart, quench exhaust). Cleared for resale with a clean site-decommission audit and a signed chain-of-custody letter from the hospital. Shielding is customer-supplied — we can pair the unit with a certified installer on quote.

Save
Medical MRI scannergood
Buyer protection

Funds held in Stripe Connect escrow. Signed handover docs + inspection report release the payout. 7-day inspection window on delivery.

Overview

What you're buying.

Plain language, no jargon.

A 2019 MedImage MI-3000T 3.0-tesla MRI system, decommissioned from a Dutch regional hospital following a full equipment refresh. Helium level at 98% (topped-up 01/2026), 4,210 scan-hours since last cold-ramp. Includes the 70 cm wide-bore magnet, 48-channel RF chain, and the full control room bundle (operator workstation, patient monitoring cart, quench exhaust). Cleared for resale with a clean site-decommission audit and a signed chain-of-custody letter from the hospital. Shielding is customer-supplied — we can pair the unit with a certified installer on quote.

Specifications

What the machine is.

Identity
Manufacturer
MedImage
Model
MI-3000T
Year of build
2019
Serial number
MI3T-2019-NL-0042
Magnet
Field strength
3.0T
Bore
70cm
Helium level
98%
RF
Channels
48
Usage
Scan hours
4,210h
Power
Supply
3-phase 400 V / 125 A
Condition

Where the wear is.

3T magnet & cryostata

Helium level 98%. Cold-ramp record clean. No quench events recorded.

RF chain · 48 channelsa

All channels pass SNR check against factory baseline. No coil replacement since install.

Gradient coilb

Slight cooling-loop ageing, but duty cycles remain within spec. Planned fluid swap at next service.

Operator consolea

Workstation imaged fresh; DICOM worklist integration tested against a dummy PACS.

Inspection

When we looked inside.

3T magnet inspection at the Dutch regional hospital following decom. Helium level 98% with continuous cool throughout. All 48 RF channels pass SNR check against factory baseline. Gradient coil duty-cycle within spec, light cooling-loop ageing noted. 10-page report attached.

  1. 09 Mar 202609:30 UTC
    On-site decom inspection

    Inspector arrived at the hospital. Cryostat + helium levels documented pre-disconnect.

    S. De Vries· Cert. ID 3044
  2. 10 Mar 202614:00 UTC
    RF + gradient tests

    All 48 RF channels pass SNR baseline. Gradient coil logs reviewed, duty-cycle within spec.

    S. De Vries· Cert. ID 3044
  3. 11 Mar 202610:45 UTC
    Chain-of-custody signed

    Hospital QA countersigned decom letter. Asset chain handed to Rekyndo custody.

    Regional Hospital QA · NL
  4. 12 Mar 202611:30 UTC
    Report published

    10-page report issued — condition grade 9/10. Planned cooling-loop fluid swap at next service.

    S. De Vries· RK-IR-49211-v1
Download full report →
Documents

Everything, in the box.

Preview visible. Sign in to download files.

  • Inspection report · RK-IR-49211-v1Site-decom inspection with magnet logs. · signed by S. De Vries · Cert. 3044
    10 pages · 3.0 MBSign in →
  • Hospital decom + chain-of-custodySigned decom letter from issuing hospital. · signed by Regional Hospital QA · NL
    3 pages · 273 KBSign in →
  • Helium top-up & cold-ramp logCryostat log, January 2026 top-up.
    59 KBSign in →
  • Photo set · 34 imagesMagnet, control room, patient bore, exhaust.
    55.3 MBSign in →
Lifecycle & ESG

What buying used avoids.

CO₂ avoided22 t
Steel reused
Expected second life12.0k h

Clinical-grade 3T systems carry a disproportionately large embodied-carbon footprint. Reusing this unit avoids ~22 t of CO₂ and defers a fresh rare-metal pull by the buyer.

Verified by Rekyndo ESG desk

Questions & answers

Public questions, answered.

  • H. Vidal · Tier-3 buyer · 14 Mar

    Any record of repair events on the gradient coil? We've seen field failures on this generation.

    Seller reply · 14 Mar

    No repair events. The inspector's report notes light cooling-loop ageing (planned fluid swap at next service) but nothing field-repair-level. Duty-cycle logs are in the decom pack.

  • Dr. M. Olsen · Tier-3 buyer · 13 Mar

    Has the magnet been on continuous cool since decom, or has it been ramped down? Cold-ramp-back can be painful.

    Seller reply · 13 Mar

    Continuous helium maintenance throughout — no ramp-down. Cryostat log attached. Reinstall can be a warm connect at your facility.

Ask a question

Sign in to post a public question. Sellers usually reply within a day.

Sign in to ask →
Logistics

Getting it there.

Example routes only. Book a transport tender for a firm quote.

EXW Boston, United States
Buyer arranges pickup
Road to Rotterdam
Heavy-haul, covered
Ro-Ro to Felixstowe
Weekly sailing
Rail to Milan
Intermodal
Heavy-lift to Piraeus
Monthly sailing
Need transport, inspection, or install?

Post a service tender attached to this listing.

Start tender →
Similar listings

Other items on Rekyndo.

Sign in for price, contact, and to make offers